产品分类

您的位置:首页 > 产品中心 > HACH在线水质分析仪 > 通用控制器 > LXV404.99.00302

产品中心
产品名称: LXV404.99.00302
产品型号:
产品时间: 2017-01-17
The sc200 Universal Controller operates (1) Ultrasonic Flow Sensor is designed to give highly accurate flow and depth measurements for your open channel flow monitoring applications. From the easy-to-

产品介绍

Maximum Versatility

Standardized controller eliminates the need for a variety of dedicated controllers. Operates 1 or 2 sensors reducing inventory. Multi-channel controller operates either 1 or 2 sensors reducing inventory holding costs, and providing an inexpensive option to add a second sensor at a later time. Plug and Play operation with all Hach digital sensors. True dual sensor controller provides 4-20 mA outputs to transmit primary and secondary measurement values

Ease of Use and Confidence in Results

New display and guided calibration procedures reduce operator error. Password protected SD card reader offers a simple solution for data download and transfer. Visual warning system provides critical alerts

One Controller, Numerous Communication Options

Hach offers the largest portfolio of sensors and analyzers for water analytics with MODBUS RS232, MODBUS RS485 and Profibus® DP capability.

Use with Maintenance Free Flow Sensor

Non-Contact Ultrasonic Flow Sensor with pulse echo technology requires no routine maintenance.

What's in the box

Controller, Mounting Hardware, Basic User Manual

Specifications

Analog Output Functional Mode:Linear, Logarithmic, Bi-linear, PID

Analog Outputs:Two (Five with optional expansion module) to isolated current outputs, max 550 Ω, Accuracy:± 0.1% of FS (20mA) at 25 °C, ± 0.5% of FS over -20 °C to 60 °C range
Operational Mode: measurement or calculated value

Communication:MODBUS RS232/RS485, PROFIBUS DPV1, or HART 7.2 optional

Dimensions (H x W x D):5.7 in x 5.7 in x 7.1 in (144 mm x 144 mm x 181 mm)

Display:Graphic dot matrix LCD with LED backlighting, transreflective

Display Resolution:240 x 160 pixels

Display Size:1.9 x 2.7 in. (48 mm x 68 mm)

Electrical Certifications:EMC
CE compliant for conducted and radiated emissions:
- CISPR 11 (Class A limits)
- EMC Immunity EN 61326-1 (Industrial limits)
Safety
cETLus safety mark for:
- General Locations per ANSI/UL 61010-1 & CAN/CSA C22.2. No. 61010-1
- Hazardous Location Class I, Division 2, Groups A,B,C & D (Zone 2, Group IIC) per FM 3600 / FM 3611 & CSA C22.2 No. 213 M1987 with approved options and appropriay rated Class I, Division 2 or Zone 2 sensors
cULus safety mark
- General Locations per UL 61010-1 & CAN/CSA C22.2. No. 61010-1

Enclosure Rating:NEMA 4X/IP66

Length:7.1 in ( 181 mm )

Manual Languages:Bulgarian, Chinese (PRC), Croatian, Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Lithuanian, Polish, Portuguese (Brazil), Portuguese (Portugal), Romanian, Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish

Material Enclosures:Polycarbonate
Aluminium (powder coated)
Stainless Steel

Memory Backup:Flash memory

Mounting Configurations:Wall
Pole
Panel Mounting

Operating Temperature Range:-20 to 60 °C at 0 to 95% RH (non-condensing)

Power Requirements (Hz):50 - 60 Hz

Power Requirements (Voltage):100 - 240 V AC

Relay Functions:Scheduler (Timer), Alarm, Feeder Control, Event Control, Pulse Width Modulation, Frequency Control, and Warning

Relay: Operational Mode:Primary or secondary measurement, calculated value (dual channel only) or timer

Relays:Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A

Storage Conditions:-20 °C to 70 °C

Temperature Range:-20 to 70 °C, 0 to 95% RH non-condensing

Warranty:2 years

Weight:3.75 lbs. (1.70 kg)