产品分类

您的位置:首页 > 产品中心 > HACH实验室水质分析仪 > 哈希电化学多参数仪 > 8506000

产品中心
产品名称: 8506000
产品型号:
产品时间: 2016-12-25
Designed for your water applications, the Hach HQ40d portable meter with pH probe is an advanced meter that takes the guesswork out of measurements. HQd™ meters connect with InliCAL™ probes that au

产品介绍

Portable meter measures critical water quality parameters - without the need for multiple instruments

Two input channels for simultaneous measurement of pH, Conductivity/TDS/Salinity, Optical Dissolved Oxygen, BOD, ORP, Ammonia, Ammonium, Fluoride, Chloride, Sodium, and temperature - any InliCAL™ smart probe.

Intuitive user interface for simple operation and accurate results

Guided calibration and check standard routines reduce calibration errors. Stabilization alerts and visual measurement lock ensure that you can trust the accuracy of the results.

Trust your measurements - InliCAL™ smart probes store all calibrations in the probe

Calibration history allows quick and easy change out of probes without re-calibrating. The HQd smart system records serial numbers, current calibration data, user ID, sample ID, time, and date automatically in the data log for complete GLP traceability.

Designed for demanding conditions

Rugged, waterproof (IP67) meter provides worry-free, reliable operation in lab or field environments.

Convenient kit includes everything you need to start testing

Meter package includes HQ40d Portable Meter, refillable PHC301 pH probe with 1 m cable, CDC401 conductivity/TDS/salinity probe with 1 m cable, standard LDO101 optical dissolved oxygen probe with 1 m cable, pH buffer solutions, pH storage solution, NaCl conductivity standard, BOD bottle for DO calibration, probe stand, meter stand, 4 AA batteries, protective meter glove, power adapter, USB/DC power adapter for data transfer, quick-start guide, user manual, and documentation CD

Meter package includes HQ40d Portable Meter, refillable PHC301 pH probe with 1 m cable, CDC401 conductivity/TDS/salinity probe with 1 m cable, standard LDO101 optical dissolved oxygen probe with 1 m cable, pH buffer solutions, pH storage solution, NaCl conductivity standard, BOD bottle for DO calibration, probe stand, meter stand, 4 AA batteries, protective meter glove, power adapter, USB/DC power adapter for data transfer, quick-start guide and user manual.

Automatic Buffer Recognition:Color-coded: 4.01, 7.00, 10.01 pH; IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45 DIN: 1.09, 4.65, 9.23 User-defined custom buffer sets
Backlight:
Barometric Pressure Measurement:For automatic compensation of DO when using an LDO or LBOD probe
Benchtop:
BOD5/CBOD resolution:Available when used with Hach WIMS BOD Manager Software
Cable resistance correction:Digital - not needed
Calibration curves display:Calibration summary data logged and displayed
Calibration Intervals/Alerts/Reminder:2 hours to 7 days
Compliance:CE
Conductivity Accuracy:0.5 µS/cm
Conductivity Measurement Range:0.01 µS/cm to 400 µS/cm
Conductivity measurement: Temperature correction:Temperature correction
Conductivity resolution:0.01 µS/cm with 2 digits
Custom Calibration Standards:User-defined standard sets
Data Export:Download via USB connection to PC or flash memory device. Automatically transfer entire data log or as readings are taken.
Data Memory:500 results
Digital (inligent) electrode inputs:2 channel
Dimensions (H x W x D):7.8 in x 3.7 in x 1.2 in (197 mm x 95 mm x 30 mm)
Display:Display readings from one or two probes Simultaneous readings from two probes (HQ440d only) pH: pH, mV, temperature Conductivity: Conductivity, TDS, salinity, resistivity, temperature LDO: dissolved oxygen, pressure, temperature LBOD: dissolved oxygen, pressure, temperature ORP/Redox: mV, temperature Sodium: Sodium, mV, temperature
Display Lock Function:Continuous measurement or "press to read" mode available with averaging function for LDO measurement.
Display Type:240 x 160 Display readings from one or two probes Simultaneous readings from two probes pH: pH, mV, temperature Conductivity: Conductivity, TDS, salinity, resistivity, temperature LDO: dissolved oxygen, pressure, temperature ORP/Redox: mV, temperature Sodium: Sodium, mV, temperature
DO Measurement Range:0.01 to 20 mg/L (ppm)
DO Resolution:0.01 mg/L
Fixed Buffer Selection:IUPAC standards (DIN 19266) or Technical buffer (DIN 19267) or 4-7-10 series or user defined
GLP Features:
Inputs:M12 digital (1) for InliCAL probes
Interface Languages:13
Internal Data Storage:500
IP Rating:IP54 (Resistant to spray of water; Dust-proof)
ISE Direct Measurement Range:Yes
Languages:English, French, German, Italian, Spanish, Danish, Dutch, Polish, Portuguese, Turkish, Swedish, Czech, Russian
mV Accuracy:0.1 mV
mV Measurement Range:-1500 to 1500 mV
mV Resolution:0.1 mV
Operating Error Messages:Text messages displayed
Operating Humidity:90 % relative humidity (non-condensing)
Operating Interface:Keypad
Operating Temperature:5 to 45 °C
Operating Temperature Range:0 to 60 °C
Outputs:USB to PC / flash memory device
PC Data Transfer Software:Included
pH Measurement at stable reading:5 stabilization settings
pH Resolution:0.001 0.1 pH
Portable:
Printer:Optional accessory
Salinity Measurement Range:0 to 42 ppt
Salinity Resolution:0.01 ppt
TDS Measurement Range:0 to 50000 mg/L
TDS Resolution:0.01 mg/L
Temperature Accuracy:∓ 0.3 °C